-40%

Adscope Sprague Stethoscope, 22"

$ 12.63

Availability: 70 in stock
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Brand: Adscope
  • Modified Item: No
  • MPN: STSR
  • California Prop 65 Warning: No
  • Custom Bundle: No
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Condition: New

    Description

    Adscope Sprague Stethoscope, 22"
    The American Health Service Stethoscope comes in three different styles: single head, dual head, and sprague-rappaport. A must have piece of medical equipment for listening to heart and bowel sounds.
    Our eBay Store
    Adscope Sprague Stethoscope 22"
    Adscope Sprague Stethoscope, 22" The American Health Service Stethoscope comes in three different styles: single head, dual head, and sprague-rappaport. A must have piece of medical equipment for listening to heart and bowel sounds.
    Cautions and Warnings
    Caution: Never use stethoscope without eartips firmly locked in place._x000D_ Note: When first unpacked you Sprague tubing my experience some kinks from packaging. This is normal. To uncurl hang scope for 24 hours at room temperature._x000D_
    Directions and Dosage Instructions
    Chestpiece options_x000D_ The ADC Sprague design utilizes five different interchangeable chestpiece attachments to detect a broad frequency range in bot pediatric and adult patients. The chestpiece drum accommodates 2 different chestpiece attachments of your choice at one time. Select the type that best suits the intended patient application. Chestpiece attachments can be affixed by threading clockwise until tight. To remove twist in a counter clock-wise direction._x000D_ Selection of Chest piece_x000D_ On ADC ADSCOPE Spragues the entire chestpiece rotates 108 degrees permitting the selection of on side. (only on side is operable at a time). ADC patented valve mechanism eliminates virtually all acoustic leakage from the inoperable side. To select the side in operation hold the chestpiece stem in one hand and rotate the chestpeice with the other hand until a click is felt and heard. Ali9ght tap on the diaphragm or bell will help determine which side is in operation as well._x000D_ Chestpiece Key_x000D_ ADC proprietary chestpiece is design and slotted key allows you to tighten the periatric or adult assembly as securely as you like. Without fear of being unable to disassemble the rim in order to replace a worn or broken diaphragm._x000D_ Replacing the Diaphragm_x000D_ To replace a diaphragm remove the desired assembly by gripping the assembly firmly and turning counterclockwise. To loosen the diaphragm rim insert the key into the two slots located within the threaded portion located on the underside of the assembly. While holding the rim steady turn the key counterclockwise to loosen the rim. Remove worn diaphragm and replace with new. Reassemble rim and tighten by turning key clockwise until tight. Then reassemble diaphragm rim back onto chestpiece drum by turning clockwise until tight._x000D_ Adjusting the Binaurals_x000D_ To obtain the most comfortable acoustically sealed aural fit rotate each binaural tube approximately 15 degrees forward towards the bridge of your nose. Simply twist each tube where it enters the tubing._x000D_ Adjusting the Spring Tension in the Binaurals_x000D_ To reduce the tension grip the binaurals firmly using both hands with fingers at the center of the “Y” in the tubing thumbs at each side where the tubing branches out. Flex binaurals gradually until desired tension is obtained. To increase the tension grip the binaurals in the hand and squeeze the binaural tubes together gradually. Caution: Excessive adjustment of the spring tension could weaken the spring._x000D_ Care and Maintenance_x000D_ Avoid extreme heat cold solvent or oils._x000D_ Do not leave exposed to direct sunlight for prolonged periods of time._x000D_ Binaurals and tubing can be wiped down with alcohol or mild spray wate._x000D_ Eartips may be unscrewed from binaurlas fo a thorough cleaning._x000D_ Periodically check that eartips are tightly secured to binaurals._x000D_ Do not immerse stethoscope I any liquid or subject to steam sterilization._x000D_ if sterilization is necessary gas sterilize only._x000D_ _x000D_
    Ingredients
    Storage and Disposal Requirements
    Color
    Flavor
    Material
    Scent
    Pattern Design and Style