-40%

Adscope Sprague Stethoscope, 22"

$ 10.98

Availability: 100 in stock

Description

Adscope Sprague Stethoscope, 22"
The American Health Service Stethoscope comes in three different styles: single head, dual head, and sprague-rappaport. A must have piece of medical equipment for listening to heart and bowel sounds.
Our eBay Store
Adscope Sprague Stethoscope, 22"
Adscope Sprague Stethoscope, 22"
The American Health Service Stethoscope comes in three different styles: single head, dual head, and sprague-rappaport. A must have piece of medical equipment for listening to heart and bowel sounds.
Cautions and Warnings
Caution: Never use stethoscope without eartips firmly locked in place. Note: When first unpacked, you Sprague tubing my experience some kinks from packaging. This is normal. To uncurl, hang scope for 24 hours at room temperature.
Directions and Dosage Instructions
Chestpiece options The ADC Sprague design utilizes five different interchangeable chestpiece attachments to detect a broad frequency range in bot pediatric and adult patients. The chestpiece drum accommodates 2 different chestpiece attachments of your choice at one time. Select the type that best suits the intended patient application. Chestpiece attachments can be affixed by threading clockwise until tight. To remove, twist in a counter clock-wise direction. Selection of Chest piece On ADC ADSCOPE Spragues, the entire chestpiece rotates 108 degrees permitting the selection of on side. (only on side is operable at a time). ADC patented valve mechanism eliminates virtually all acoustic leakage from the inoperable side. To select the side in operation, hold the chestpiece stem in one hand and rotate the chestpeice with the other hand until a click is felt and heard. Ali9ght tap on the diaphragm or bell will help determine which side is in operation as well. Chestpiece Key ADC proprietary chestpiece is design and slotted key allows you to tighten the periatric or adult assembly as securely as you like. Without fear of being unable to disassemble the rim in order to replace a worn or broken diaphragm. Replacing the Diaphragm To replace a diaphragm, remove the desired assembly by gripping the assembly firmly and turning counterclockwise. To loosen the diaphragm rim, insert the key into the two slots located within the threaded portion, located on the underside of the assembly. While holding the rim steady, turn the key counterclockwise to loosen the rim. Remove worn diaphragm and replace with new. Reassemble rim, and tighten by turning key clockwise until tight. Then reassemble diaphragm rim back onto chestpiece drum by turning clockwise until tight. Adjusting the Binaurals To obtain the most comfortable acoustically sealed aural fit, rotate each binaural tube approximately 15 degrees forward, towards the bridge of your nose. Simply twist each tube where it enters the tubing. Adjusting the Spring Tension in the Binaurals To reduce the tension, grip the binaurals firmly using both hands with fingers at the center of the “Y” in the tubing, thumbs at each side where the tubing branches out. Flex binaurals gradually until desired tension is obtained. To increase the tension, grip the binaurals in the hand and squeeze the binaural tubes together gradually. Caution: Excessive adjustment of the spring tension could weaken the spring. Care and Maintenance • Avoid extreme heat, cold, solvent, or oils. • Do not leave exposed to direct sunlight for prolonged periods of time. • Binaurals and tubing can be wiped down with alcohol or mild spray wate. • Eartips may be unscrewed from binaurlas fo a thorough cleaning. • Periodically check that eartips are tightly secured to binaurals. • Do not immerse stethoscope I any liquid or subject to steam sterilization. • if sterilization is necessary, gas sterilize only.
Ingredients
Storage and Disposal Requirements
Color
Flavor
Material
Scent
Pattern Design and Style